

|

|
Material Safety Data Sheet
- PRODUCT IDENTIFICATION
Product Name** SHOCKtec Gel (Kemmler VDP original polymer) Product Code** Dry Viscoelastic Polymer w/film and foam chemical family ** Polyurethane Viscoelastic Polymer Appearance Products are of various configurations comprising dry viscoelastic polymer contained within a polyurethane film. Contains polyurethane foam.
- HAZARDOUS INGREDIENTS
NONE
- PHYSICAL DATA
The dry viscoelastic polymer contained inside has shore 00 hardness less than zero and is fungus resistant by ASTM D1924-63. The elastic film containing the polymer has tensile strength of 6000 PSI and elongation of 300%. The padding may be washed with water containing detergent and sanitized with any agent used in hospitals for this application.
- FIRE DATA
The elastic film which contains the dry viscoelastic softens at about 275 degrees F. The combination of dry viscoelastic polymer and the containing elastic film is rated as self-extinguishing by the ASTM D1692-68. Extinguishing Media: Dry Chemical, Carbon Dioxide, Chemical Foam, and Water
- HUMAN HEALTH DATA
Primary routes of entry ** Ingestion. Note- Products have been in use for 20 years in the form of wheelchair cushions and bed pads with no deleterious effects to humans.
- HUMAN EFFECTS
Inhalation ** None Ingestion ** No study has been made Eye Contact ** None Skin Contact ** Products comprised of Dry Viscoelastic Polymer contained in the elastic film are non-allergenic by Schwartz Patch Test.
- EMERGENCY FIRST AID PROCEDURES
None Required
- EMPLOYEE PROTECTION
Eye Protection ** None Required Skin Protection ** None Required Respiratory Protection ** None Required Ventilation ** None Required Hygienic Practices Wash hands prior to eating and smoking
- REACTIVITY DATA
Stability ** Stable –40 to 212 degrees F. Polymerization ** None Hazardous Decomposition ** Only in case of fire or exposure to temperatures in excess of 275 degrees F.
- SPILL OR LEAK PROCEDURES
In case of puncture of the elastic skin, the product will not leak. IT MAY BECOME STICKY OR TACKY AT THE BREAK. If so, clean the area with alcohol and apply magic mending scotch tape to seal the break.
- SPECIAL PRECAUTIONS AND STORAGE
Products are not adversely affected by temperatures in the –40 to 212 degree F. However, it is best to store at ambient room temperature. Products are sensitive to ultraviolet light. Protect the product from the direct sunlight.
- SHIPPING DATA
D.O.T. Shipping ** Rubber Mats: Medical Use only Technical Shipping Name ** Synthetic Rubber FRT. Class Pkg. ** Rubber Mats: Item 134230,Mac Non Regulated
MATERIAL SAFETY DATA SHEET
- PRODUCT IDENTIFICATION
Product Name** SHOCKtec Air2Gel (Kemmler Lite & UltaLite) Product Code** Air-Frothed Viscoelastic Dry Polymer with treated polyurethane film substrate (carrier film) and foam chemical family. ** Clouded Polyurethane Viscoelastic Polymer Appearance ** Products are sold in various size sheets, with a TPU film substrate and often marketed with a peel off poly-ethylene film attached to the second flat side. Air-Frothed viscoelastic dry polymer (polyurethane foam) is contained between the base substrate, the polyurethane film, and peel off polyethylene film or a polyester fabric.
- HAZARDOUS INGREDIENTS
NONE
- PHYSICAL DATA
The dry viscoelastic polymer contained inside has shore 00 hardness less than zero and is fungus resistant by ASTM D1924-63. The elastic film containing the polymer has tensile strength of 6000 PSI and elongation of 300%. The padding may be washed with water containing detergent and sanitized with any agent used in hospitals for this application.
- FIRE DATA
The treated polyurethane film which serves as the base substrate (carrier film) for the air-frothed viscoelastic dry polymer softens at about 300 degrees F. The polyethylene film which serves as the peel off film softens at about 275 degrees F. The combination of air-frothed viscoelastic dry polymer and the attached films, treated polyurethane and polyethylene, combust at approximately 600 degrees F. Extinguishing Media: Dry Chemical, Carbon Dioxide, Chemical Foam, and Water
- HUMAN HEALTH DATA
Primary routes of entry ** Ingestion. Note- Products have been in use for 20 years in the form of wheelchair cushions and bed pads with no deleterious effects to humans.
- HUMAN EFFECTS
Inhalation ** None Ingestion ** No study has been made Eye Contact ** None Skin Contact ** Products comprised of Air-Frothed Viscoelastic Dry Polymer contained in the films are non-allergenic by Schwartz Patch Test.
- EMERGENCY FIRST AID PROCEDURES
None Required
- EMPLOYEE PROTECTION
Eye Protection ** None Required Skin Protection ** None Required Respiratory Protection ** None Required Ventilation ** None Required Hygienic Practices Wash hands prior to eating and smoking
- REACTIVITY DATA
Stability ** Stable –40 to 212 degrees F. Polymerization ** None Hazardous Decomposition ** Only in case of fire or exposure to temperatures in excess of 275 degrees F.
- SPILL OR LEAK PROCEDURES
In case of puncture of the elastic skin, the product will not leak. IT MAY BECOME STICKY OR TACKY AT THE BREAK. If so, clean the area with alcohol and apply magic mending scotch tape to seal the break.
- SPECIAL PRECAUTIONS AND STORAGE
Products are not adversely affected by temperatures in the –40 to 212 degree F. However, it is best to store at ambient room temperature. Products are sensitive to ultraviolet light. Protect the product from the direct sunlight.
- SHIPPING DATA
D.O.T. Shipping ** Rubber Mats: Medical Use only Technical Shipping Name ** Synthetic Rubber FRT. Class Pkg. ** Rubber Mats: Item 134230,Mac Non Regulated
|
|
|