Material Safety Data Sheet



  1. PRODUCT IDENTIFICATION
    Product Name** SHOCKtec Gel (Kemmler VDP original polymer)
    Product Code** Dry Viscoelastic Polymer w/film and foam chemical family
    ** Polyurethane Viscoelastic Polymer Appearance
    Products are of various configurations comprising dry viscoelastic polymer contained within a polyurethane film. Contains polyurethane foam.
  2. HAZARDOUS INGREDIENTS
    NONE
  3. PHYSICAL DATA
    The dry viscoelastic polymer contained inside has shore 00 hardness less than zero and is fungus resistant by ASTM D1924-63. The elastic film containing the polymer has tensile strength of 6000 PSI and elongation of 300%. The padding may be washed with water containing detergent and sanitized with any agent used in hospitals for this application.
  1. FIRE DATA
    The elastic film which contains the dry viscoelastic softens at about 275 degrees F. The combination of dry viscoelastic polymer and the containing elastic film is rated as self-extinguishing by the ASTM D1692-68.
    Extinguishing Media: Dry Chemical, Carbon Dioxide, Chemical Foam, and Water
  2. HUMAN HEALTH DATA
    Primary routes of entry ** Ingestion. Note- Products have been in use for 20 years in the form of wheelchair cushions and bed pads with no deleterious effects to humans.
  3. HUMAN EFFECTS
    Inhalation ** None
    Ingestion ** No study has been made
    Eye Contact ** None
    Skin Contact ** Products comprised of Dry Viscoelastic Polymer contained in the elastic film are non-allergenic by Schwartz Patch Test.
  4. EMERGENCY FIRST AID PROCEDURES
    None Required
  5. EMPLOYEE PROTECTION
    Eye Protection ** None Required
    Skin Protection ** None Required
    Respiratory Protection ** None Required
    Ventilation ** None Required
    Hygienic Practices Wash hands prior to eating and smoking
  6. REACTIVITY DATA
    Stability ** Stable –40 to 212 degrees F.
    Polymerization ** None
    Hazardous Decomposition ** Only in case of fire or exposure to temperatures in excess of 275 degrees F.
  7. SPILL OR LEAK PROCEDURES
    In case of puncture of the elastic skin, the product will not leak. IT MAY BECOME STICKY OR TACKY AT THE BREAK. If so, clean the area with alcohol and apply magic mending scotch tape to seal the break.
  8. SPECIAL PRECAUTIONS AND STORAGE
    Products are not adversely affected by temperatures in the –40 to 212 degree F. However, it is best to store at ambient room temperature. Products are sensitive to ultraviolet light. Protect the product from the direct sunlight.
  9. SHIPPING DATA
    D.O.T. Shipping ** Rubber Mats: Medical Use only
    Technical Shipping Name ** Synthetic Rubber
    FRT. Class Pkg. ** Rubber Mats: Item 134230,Mac
    Non Regulated

 

MATERIAL SAFETY DATA SHEET

  1. PRODUCT IDENTIFICATION
    Product Name** SHOCKtec Air2Gel (Kemmler Lite & UltaLite)
    Product Code** Air-Frothed Viscoelastic Dry Polymer with treated polyurethane film substrate (carrier film) and foam chemical family.
    ** Clouded Polyurethane Viscoelastic Polymer Appearance
    ** Products are sold in various size sheets, with a TPU film substrate and often marketed with a peel off poly-ethylene film attached to the second flat side. Air-Frothed viscoelastic dry polymer (polyurethane foam) is contained between the base substrate, the polyurethane film, and peel off polyethylene film or a polyester fabric.
  2. HAZARDOUS INGREDIENTS
    NONE
  3. PHYSICAL DATA
    The dry viscoelastic polymer contained inside has shore 00 hardness less than zero and is fungus resistant by ASTM D1924-63. The elastic film containing the polymer has tensile strength of 6000 PSI and elongation of 300%. The padding may be washed with water containing detergent and sanitized with any agent used in hospitals for this application.
  1. FIRE DATA
    The treated polyurethane film which serves as the base substrate (carrier film) for the air-frothed viscoelastic dry polymer softens at about 300 degrees F. The polyethylene film which serves as the peel off film softens at about 275 degrees F.
    The combination of air-frothed viscoelastic dry polymer and the attached films, treated polyurethane and polyethylene, combust at approximately 600 degrees F.
    Extinguishing Media: Dry Chemical, Carbon Dioxide, Chemical Foam, and Water
  2. HUMAN HEALTH DATA
    Primary routes of entry ** Ingestion. Note- Products have been in use for 20 years in the form of wheelchair cushions and bed pads with no deleterious effects to humans.
  3. HUMAN EFFECTS
    Inhalation ** None
    Ingestion ** No study has been made
    Eye Contact ** None
    Skin Contact ** Products comprised of Air-Frothed Viscoelastic Dry Polymer contained in the films are non-allergenic by Schwartz Patch Test.
  4. EMERGENCY FIRST AID PROCEDURES
    None Required
  5. EMPLOYEE PROTECTION
    Eye Protection ** None Required
    Skin Protection ** None Required
    Respiratory Protection ** None Required
    Ventilation ** None Required
    Hygienic Practices Wash hands prior to eating and smoking
  6. REACTIVITY DATA
    Stability ** Stable –40 to 212 degrees F.
    Polymerization ** None
    Hazardous Decomposition ** Only in case of fire or exposure to temperatures in excess of 275 degrees F.
  7. SPILL OR LEAK PROCEDURES
    In case of puncture of the elastic skin, the product will not leak. IT MAY BECOME STICKY OR TACKY AT THE BREAK. If so, clean the area with alcohol and apply magic mending scotch tape to seal the break.
  8. SPECIAL PRECAUTIONS AND STORAGE
    Products are not adversely affected by temperatures in the –40 to 212 degree F. However, it is best to store at ambient room temperature. Products are sensitive to ultraviolet light. Protect the product from the direct sunlight.
  9. SHIPPING DATA
    D.O.T. Shipping ** Rubber Mats: Medical Use only
    Technical Shipping Name ** Synthetic Rubber
    FRT. Class Pkg. ** Rubber Mats: Item 134230,Mac
    Non Regulated